BYTNN - KODAK AQUA-IMAGE NEGATIVE FINISHER, MX 1540-1

  • MSDS: BYTNN
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: KODAK AQUA-IMAGE NEGATIVE FINISHER, MX 1540-1
  • National Stock Number: 6750-00D000496
Product Identification

Product ID:KODAK AQUA-IMAGE NEGATIVE FINISHER, MX 1540-1
MSDS Date:11/03/1993
FSC:6750
NIIN:00D000496
MSDS Number: BYTNN

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 716-722-5151

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 80-85%


DEXTRINE

CAS: 9004-53-9

RTECS: HH9450000

Fraction By Weight: 5-10%


SODIUM PHOSPHATE, MONOBASIC

CAS: 7558-80-7

RTECS: WA1900000

Fraction By Weight: 5-10%


POLY(1-VINYL-2-PYRROLIDINONE)

CAS: 9003-39-8

RTECS: TR8160000

Fraction By Weight: 1-5% %


SODIUM PHOSPHATE, TRIBASIC (SARA III)

CAS: 10124-56-8

RTECS: OY3675000

Fraction By Weight: 1-5% %

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALE: EXPECTED TO BE A LOW HAZARD
FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN. MAY CAUSE
TRANSIENT IRRITATION. SKIN: LOW HAZARD FOR RECOMMENDED HANDLING.
INGEST: EXPECTED TO BE A LOW IN GESTION HAZARD.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:EYE IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALE: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYE: ANY MATERIAL THAT CONTACTS EYE
SHOULD BE WASHED OUT IMMEDIATELY W/WATER. GET MEDICAL ATTENTION IF
SYMPTOMS OC CUR. SKIN: WASH W/SOAP & WATER. GET MEDICAL ATTENTION
IF SYMPTOMS OCCUR. INGEST: DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL
ATTENTION.

Fire Fighting

Flash Point:NON-COMBUSTIBLE
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:NONE (NONCOMBUSTIBLE).
Unusual Fire/Explosion Hazard:NONE (NONCOMBUSTIBLE).

Accidental Release

Spill Release Procedures:FLUSH TO SEWER WITH LARGE AMOUNTS OF WATER.
OTHERWISE ABSORB SPILL W/VEMICULITE OR TOTHER INERT MATERIAL. THEN
PLACE IN CONTAINER FOR CHEMICAL WASTE. CLEAN SURFACE THOROUGHLY TO
REMOVE RESIDUAL CONTAM INATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE WITH ADEQUATE VENTILATION. KEEP
CONTAINER CLOSED.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES HSOULD BE MATCHED TO CONDITIONS
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS OR GOGGLES
Other Protective Equipment:EYE BATH, WASHING FACILITIES, SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. GOOD INDUSTRIAL
HYGIENE PRACTICES SHOULD BE FOLLOWED.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18MM
Vapor Density:0.6
Spec Gravity:1.075
pH:4.4
Solubility in Water:COMPLETE.
Appearance and Odor:LIQUID, DARK BROWN COLOR, WAXY ODOR.
Percent Volatiles by Volume:85

Stability

Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS & CONTAMINANTS WITH WHICH THE MATL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, LOCAL LAWS. FLUSH TO SEWER WITH LARGE AMOUNTS
OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.